BPC PowerMaster El manual del propietario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
23
Appendix
Operation of LEDs
O
n power up, the Red LED on your BPC2 will turn on for 1 second. If it remains on
continuously, this indicates a problem with the LCS PDI cabling or your command base.
During operation, the Red LED flickers when commands are passing through the
LCS PDI bus.
Specifications of the LCS BPC2
Mechanical
• Size:3.7”x2.7”x1.2”
• Mounting:Two#4panheadsheetmetalscrews
Electrical
• InputPDIsupplycurrent:50mA
External Relay Power/Accessory Transformer
• Inputrelayvoltage:12-14VAC
• Inputrelaycurrent:~60mAx8(~500mAmax)
Relay Contact Specifications
• Maximumrelaycontactvoltage:24volts(ACorDC)
• Maximumrelaycontactcurrent:20amps
Vista de pagina 22