Wiring Your Block Power Controller
Connecting the COMM wires
T
o receive your commands, the BPC will need to communicate with the Command Base.
Messages from the Command Base are sent through the Command Base Cable (available
separately, 6-14191 for a 6’ cable or 6-14195 for a 20’ cable). Follow these steps and refer to
Figure 1 on page 4 to connect your BPC unit to the Command Base with the cable.
Your BPC is equipped with two additional COM terminals, AX + and AX-. At this
time, leave these terminals empty. These are intended for future capabilities. Do not
wire DAT and COMM wiring to the AX+ and AX- terminals.
1. Connect the DB9 Connector at the end of the Command Base Cable (the
end that looks like a computer cable) to the COMPUTER terminal on the
Command Base.
2. Connect the red wire at the other end of the Command Base Cable to the
DAT terminal on the BPC.
3. Connect the green wire to the COM terminal on the BPC.